District Energy · Natural Refrigerants
How natural refrigerants can help decarbonize district systems
Campuses and municipalities are rethinking their thermal infrastructure
This article was originally published in District Energy magazine, the quarterly publication of the International District Energy Association (IDEA), 2026.
It doesn't hurt to sometimes remind ourselves that district energy at its essence centralizes thermal energy systems. A central plant produces steam, hot water or chilled water and distributes it across multiple buildings through an underground piping network.
The efficiency advantages are substantial. Research has shown that centralizing thermal production can reduce primary energy use by at least 50% compared with maintaining stand-alone boilers, chillers and associated equipment in individual buildings. The city of Mississauga, Ontario, has found that low-carbon district energy systems when paired with heat pumps can eliminate 90% of greenhouse gas reductions compared with standalone systems.
District systems reduce operations and maintenance costs by eliminating the need for mechanical equipment in every building. They also provide fuel flexibility, enabling the integration of renewable energy sources such as solar power, geo-exchange or even waste heat without modifying building infrastructure

The CIMCO primary ammonia heat pump that ties into a geo-exchange glycol borefield that supports the district energy system for the Blatchford redevelopment area of Edmonton. CIMCO
For universities and municipalities managing large building portfolios, district energy offers economies of scale that individual systems cannot match.
The Unique Challenges of Aging Infrastructure
Many universities and hospitals operate first-generation legacy steam systems designed for temperatures above 248 F (120 C).
Today, these systems face multiple challenges. Steam boilers rely on fossil fuels and generate significant emissions. Chillers may still use HFC refrigerants with high global warming potential – refrigerants that are being phased out. Maintenance costs rise as equipment deteriorates. What once represented state-of-the-art engineering now creates both environmental and operational liability.
Facilities looking to decarbonize legacy steam systems have two paths forward. The first involves converting to low-temperature hot water distribution, which pairs well with hydronic heat pumps and improves system efficiency. However, this requires replacing entire piping networks. Facilities must account for downtime and disruption. For institutions that cannot shut down operations for extended periods, full conversion may not be practical.
The second path is simpler: Replace fossil fuel boilers with steam-generating heat pumps. The existing piping infrastructure remains in place and building connections remain unchanged. Research shows that steam heat pumps can produce output at temperatures up to 572 F (300 C), matching legacy highpressure systems.
Proven technology, favorable lifecycle economics and low risk of regulatory obsolescence.
For new construction, fourthgeneration (see sidebar, "From one generation to the next") hot water systems are often optimal. For legacy installations, steam heat pumps offer a more practical option.
Facilities can take a phased approach, operating heat pumps in parallel with existing boilers during peak loads. Heat pumps can recover waste heat from cooling processes and reinject it into heating loops. Pairing with thermal storage enables facilities to manage peak demand and optimize electricity use.
Refrigerant Choice and Its Many Implications
Choosing a refrigerant has implications beyond health and the environment. It also shapes performance, operating costs and regulatory risk.
Natural refrigerants like ammonia (R717) and CO2 (R744) operate over a wider temperature range, offering fundamental performance advantages over fluorinated greenhouse gas, or f-gas, alternatives. CIMCO's ammonia hot-water heat pumps typically deliver heat up to 203 F (95C), while specialized heat pumps can reach 302 F (150 C). F-gases have narrower operating ranges, limiting their effectiveness in district heating.
Heat pumps commonly achieve a heating co-efficiency of performance, or COP, of 4 or more, whereas a gas boiler operating at 90% efficiency generally has a COP of about only 0.9. The thermodynamic properties of ammonia specifically make it inherently more efficient than f-gases.
Natural-refrigerant heat pumps address all three emission scopes. Replacing gas boilers eliminates on-site combustion (Scope 1), while natural refrigerants (with global warming potential, or GWP, of ≤ 1) contribute virtually no fugitive emissions. They also use less electricity than f-gas alternatives (Scope 2), and f-gases are energyintensive to produce (Scope 3). When powered by renewable energy, naturalrefrigerant heat pumps become a nearzero carbon energy source, eliminating both direct and indirect emissions.
Some facilities consider hydrofluoroolefins, or HFOs, to be a middle-ground solution. However, research by the German Environment Agency indicates problematic degradation pathways. When R-1234ze decomposes, it produces R-23, which has a GWP of 14,800. HFOs are facing restrictions in Europe and are likely to be phased out.
F-gases also contribute to contamination by PFAS, or "forever chemicals." Trifluoroacetic acid (TFA) is a degradation product of many fluorinated refrigerants, including R-1234yf. It is a toxic, persistent chemical that can contaminate drinking water. There is no known way to remove TFA from the water cycle.
Natural refrigerants sidestep these concerns. Ammonia and CO2 contain no fluorine, so they are not PFAS compounds and do not produce TFA. They face none of the phase-out threats associated with f-gases.
The Blatchford housing redevelopment in Edmonton, Alberta, demonstrates what is possible when natural refrigerant systems are incorporated from the start. This fifth-generation system employs a CIMCO 2-MW ammonia heat pump integrated with a geo-exchange field of 570 boreholes, each 500 feet (150 meters) deep. The system supplies heating and cooling through a two-pipe distribution loop, with temperatures boosted by heat pumps at each residence. The first-stage heat pump produces a shaft COP of 10 when operated at the district energy sharing system utility design temperatures, delivering energy to household heat pumps.
The design reduces complexity by reversing the refrigerant cycle rather than the hydronic loop, thereby eliminating the need for additional heat exchangers on either side. The results have exceeded expectations. The system has maintained full heating output at a source temperature as low as -40 F/C. The community emits approximately 75% fewer GHG emissions than standard residential developments. The project's success paved the way for a second phase using the same approach, and a third phase is in development.
Risks Associated With Upgrade Delays
Regulatory pressure is accelerating globally. HFCs face aggressive phase-down under international agreements, and the EU is phasing them out by 2050, with sectoral bans already in place. HFOs face a similar phaseout. North American regulations typically follow European precedent within several years.
Additionally, carbon pricing continues to rise. Delaying means compounding costs from carbon taxes, refrigerant penalties and equipment replacement.
Perhaps most important, delaying also creates the risk of stranding assets. New equipment that uses HFCs or HFOs today may require replacement as regulations tighten. Commercial-grade f-gas systems also face shorter lifespans and rising service costs as these refrigerants become scarce. CIMCO's industrial-grade natural refrigerant systems, by contrast, are designed to operate for 30 years or more. This fundamentally changes the lifecycle-cost calculation.
For universities, municipalities and companies managing aging thermal infrastructure, the math is straightforward: proven technology, favorable lifecycle economics and low risk of regulatory obsolescence. The question is not whether to transition to natural-refrigerant heat pumps, but how quickly.
Connect with CIMCO today to learn more.

.jpg?sfvrsn=41a2d622_1)